If there's no pump output from the boiler and nothing in the boiler's manufacturer's instructions to say otherwise, I would assume (or rather deduce!) that a pump overrun. Thanks Andy for the link to Boulter Buderus for the Camray 5 oil burner. Boulter Camray 2 Boiler Manual. View and Download Boulter Camray 5 installation & maintenance manual online. Boulter Camray 5. Boulter Buderus will be.

I have a boulter camray quartet oil fired boiler, as of this morning it does not seem to be firing up. There is plenty of oil in the tank and I cannot find the manual to see if that had any info. There is a 'lockout' light that is on but I can't say if that was normally on or not.

Anyone any tips or suggestions? -----------== Posted via Newsfeed.Com - Uncensored Usenet News ==---------- The #1 Newsgroup Service in the World! -----= Over 100,000 Newsgroups - Unlimited Fast Downloads - 19 Servers =----- Dennis Wynes 05.02.03 8:19. 'Dennis Wynes' wrote in news:b1rdjp$nkc$: Hm, that did something but not any good. It did allow the flame to start but it just cut out again very quickly and a bit of smoke coming out of the unit, looks like some part of the fan unit or something that looks like one has gone bad. Any more comments/ideas?

-----------== Posted via Newsfeed.Com - Uncensored Usenet News ==---------- The #1 Newsgroup Service in the World! -----= Over 100,000 Newsgroups - Unlimited Fast Downloads - 19 Servers =----- Dennis Wynes 06.02.03 1:40. I know a picture is worth a thousand words but here's the fault finding bit from my Camray 2, hope it helps! Microsoft Access Overflow Error Reports there. D - FAULT-FINDING D/1. Immediately the burner stops for any abnormal reason, the red lamp (2) on the burner casing will light, unless there has been a failure in the electric power supply to the burner, due to the burning out of either a fuse or the red lamp. When the red lamp is shining, the controls of the burner are at “lock-out”, and can remain so without any danger.

The burner can only be restarted manually by pressing the re-set button (2) in which the red lamp is incorporated. Having waited for at least 5 minutes with the burner at “lock-out”, the user should firmly press the re-set button(2) and then pay careful attention to what happens.

He should try to single out which of the faults listed below is present. The burner starts, flame is established within the boiler and the burner does not return to “lock-out”: Obviously the cause of failure was only temporary, such as a sudden change in voltage, and no further action is required. The burner starts, flame is established within the boiler, but the burner returns to “lock—out”: — polish the front surface of the photo cell (1) with a dry cloth; — make sure that the boiler tubes or flue ways are not blocked by soot, and arrange for them to be cleaned, should this be the case; — repeat the action shown at D/3. The burner starts, but no flame is established within the boiler, and the burner returns to “lock-out”: Make sure that atomized oil is being delivered by the nozzle (6) Should no fuel be sprayed out:. Kmspico 8 3 Windows And Office Activator Download. Turn off the main switch; — take off the locking nut (3), move the burner backwards on its hinge (5) away from the frontplate, if there is no hinge remove the burner from the boiler and, after the maintenance operations, remount it onto the boiler in the way illustrated on figure 1.